UNITRONIC® LiYCY-CY

Naziv
Koda izdelka
Testna napetost
Max. conductor resistance at 20 °C
Nominal cross section conductor (mm2)
Cena
Količina
+
UNITRONIC® LiYCY CY 2x0,25
0032302
1.2 kV
79 ?/km
0.25 mm2
2,49 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Informativni dobavni rok: 5-8 delovnih dni. Predviden dobavni rok za izbrano količino prosimo preverite v košarici.
+
UNITRONIC® LiYCY CY 3x0,25
0032303
1.2 kV
79 ?/km
0.25 mm2
2,94 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Informativni dobavni rok: 5-8 delovnih dni. Predviden dobavni rok za izbrano količino prosimo preverite v košarici.
+
UNITRONIC® LiYCY CY 4x0,25
0032304
1.2 kV
79 ?/km
0.25 mm2
3,70 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Informativni dobavni rok: 5-8 delovnih dni. Predviden dobavni rok za izbrano količino prosimo preverite v košarici.
+
UNITRONIC® LiYCY CY 5x0,25
0032305
1.2 kV
79 ?/km
0.25 mm2
6,68 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Informativni dobavni rok: 5-8 delovnih dni. Predviden dobavni rok za izbrano količino prosimo preverite v košarici.

Benefits

  • Shielding individual wires reduces crosstalk both between adjacent cables and between the wires within the same cable.
  • With robust, flexible and resistant PVC outer sheath.
  • Ideal protection against electromagnetic interference, provided by a copper stranded shielding over each conductor and an additional copper stranded shielding acting as an overall shield for the Cable.
  • Overall braid minimises electrical interference
  • Individually screened cores minimise crosstalk between cables routed in parallel

Applications

  • Can be used universally at machine interfaces for many applications for data and signal transmission in the low-frequency range.
  • Especially for environments where electromagnetic compatibility (EMC) is required.
  • For flexible use.
  • Can be used in dry and damp rooms.
  • Dry or damp rooms
  • When a lossless transmission of data has to be guaranteed in fields with strong interference, cables with individually-screened cores and an additional overall screening are used
  • For use in control, regulation and measurement circuits.

Notes

  • Please find our standard lengths at: www.lappkabel.de/kabel-standardlaengen.
  • If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.

KONTAKTIRAJTE NAS

Pošljite nam E-mail ali pa nas pokličite na +386 2 42 13 550