Naziv
Koda izdelka
Testna napetost
Nazivni presek vodnika (mm2)
Nazivni presek koncentričnega vodnika
Cena
Količina
+
NYCY 2x1,5 RE/1,5 0,6/1kV
15503003
4 kV
1.5 mm2
1.5 mm2
2,02 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 3x1,5 RE/1,5 0,6/1kV
15503103
4 kV
1.5 mm2
1.5 mm2
1,85 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 3x2,5 RE/2,5 0,6/1kV
15503113
4 kV
2.5 mm2
2.5 mm2
3,02 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 4x1,5 RE/1,5 0,6/1kV
15503203
4 kV
1.5 mm2
1.5 mm2
2,63 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 4x2,5 RE/2,5 0,6/1kV
15503213
4 kV
2.5 mm2
2.5 mm2
3,50 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 4x4 RE/4 0,6/1kV
15503223
4 kV
4 mm2
4 mm2
4,81 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 4x6 RE/6 0,6/1kV
15503233
4 kV
6 mm2
6 mm2
6,37 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 7x1,5 RE/2,5 0,6/1kV
1550330
4 kV
1.5 mm2
2.5 mm2
4,21 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 12x1,5 RE/2,5 0,6/1kV
1550332
4 kV
1.5 mm2
2.5 mm2
5,47 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 24x1,5 RE/6 0,6/1kV
1550337
4 kV
1.5 mm2
6 mm2
9,74 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 7x2,5 RE/2,5 0,6/1kV
1550350
4 kV
2.5 mm2
2.5 mm2
5,22 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 16x2,5 RE/6 0,6/1kV
1550355
4 kV
2.5 mm2
6 mm2
10,30 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Rok dobave sporočimo po obdelavi naročila.
+
NYCY 2x2,5 RE/2,5 0,6/1kV
1550299
4 kV
2.5 mm2
2.5 mm2
2,56 €
*
Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 3x4 RE/4 0,6/1kV
15503123
4 kV
4 mm2
4 mm2
4,19 €
*
Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 3x6 RE/6 0,6/1kV
1550313
4 kV
6 mm2
6 mm2
5,47 €
*
Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NYCY 7x4 RE/4 0,6/1kV
1550322
4 kV
4 mm2
4 mm2
7,15 €
*
Na zalogi, predviden rok dobave 5-8 delovnih dni.

Benefits

  • An additional outer copper conductor is positioned concentrically around the core sheath and can be used as protective cable conduits (PE), protective and neutral conductors (PEN) or screening.
  • Suitable for direct underground installation thanks to tough insulation and sheath material (PVC). The robust materials protect against harmful environmental influences and chemicals.
  • A common core wrapping made of a filling compound ensures additional strength of the cable.
  • A cross-conductive copper tape coil around the concentric conductor reduces inductance.
  • VDE-certified cable with ?VDE? testing mark for proven reliability and quality.
  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection at www.lappkabel.de/cpr.
  • Concentric conductor above all as PE

Applications

  • Can be used universally for connecting the power supply in buildings and industrial facilities.
  • For fixed installation in water, air, earth and concrete. In the ground, the minimum installation depth without additional, suitable protection is 0.6 m, and at least 0.8 m under roads.
  • Suitable for energy distribution in power and converter stations.
  • Power and control cable for fixed installation in the following applications:
  • For indoor and outdoor use
  • In concrete with a temperature below the maximum cable operating temperature of +70 °C according to the VDE standard HD 603/VDE 0276-603 - Part 3-G (point 4) governing PVC cables for direct burial
  • Burial without additional, suitable underground protection according to VDE standard HD 603/VDE 0276-603 - Part 3-G (point 4) governing PVC cables for direct burial: normal minimum installation depth 0.6 m, but at least 0.8 m under roads
  • Suitable for outdoor use, subject to the temperature range.
  • Suitable for medium mechanical stress.
  • Can be used in dry, damp or wet environments.

Documentation

Notes

  • Please find our standard lengths at: www.lappkabel.de/kabel-standardlaengen.
  • If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Trade product, not a LAPP product.

KONTAKTIRAJTE NAS

Pošljite nam E-mail ali pa nas pokličite na +386 2 42 13 550