Naziv
Koda izdelka
Testna napetost
Max. conductor resistance at 20 °C
Nominal cross section conductor (mm2)
Cena
Količina
+
NAYY-J 4x35 RE 0,6/1kV
1552010
4 kV
0.868 ?/km
35 mm2
3,67 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 4x50 SE 0,6/1kV
1552011
4 kV
0.641 ?/km
50 mm2
4,64 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 4x70 SE 0,6/1kV
1552012
4 kV
0.443 ?/km
70 mm2
6,41 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 4x95 SE 0,6/1kV
1552013
4 kV
0.32 ?/km
95 mm2
8,70 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 4x120 SE 0,6/1kV
1552014
4 kV
0.253 ?/km
120 mm2
10,87 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 4x150 SE 0,6/1kV
1552015
4 kV
0.206 ?/km
150 mm2
12,59 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 4x185 SE 0,6/1kV
1552016
4 kV
0.164 ?/km
185 mm2
15,69 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 4x240 SE 0,6/1kV
1552017
4 kV
0.1125 ?/km
240 mm2
20,55 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-O 1x300 RM 0,6/1kV
1552022
4 kV
0.1 ?/km
300 mm2
6,45 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-O 1x120 RM 0,6/1kV
3036549
4 kV
0.253 ?/km
120 mm2
2,78 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-O 1x150 RM 0,6/1kV
3036550
4 kV
0.206 ?/km
150 mm2
3,32 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-O 1x185 RM 0,6/1kV
3036551
4 kV
0.164 ?/km
185 mm2
4,08 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Ni zaloge, predviden rok dobave: 20. 01. 2026.
+
NAYY-O 1x240 RM 0,6/1kV
3036552
4 kV
0.1125 ?/km
240 mm2
5,25 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-O 1x50 RM 0,6/1kV
1550056
4 kV
0.641 ?/km
50 mm2
1,45 €
*
Min. količina za naročanje: 10000
Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 1x120 RM 0,6/1kV
3036589
4 kV
/
120 mm2
2,78 €
*
Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 1x150 RM 0,6/1kV
381150214
4 kV
/
150 mm2
3,26 €
*
Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 1x400 RM 0,6/1kV
1552115
4 kV
/
400 mm2
8,20 €
Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 1x240 RM 0,6/1kV
38801960
4 kV
/
240 mm2
5,25 €
*
Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 1x300 RM 0,6/1kV
38801969
4 kV
/
300 mm2
6,45 €
*
Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
NAYY-J 1x185 RM 0,6/1kV
381150215
4 kV
/
185 mm2
4,08 €
*
Na zalogi, predviden rok dobave 5-8 delovnih dni.

Benefits

  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.
  • VDE-certified cable with ?VDE? testing mark for proven reliability and quality.
  • Insulated aluminium conductors are single or multi-wire, round or sector-shaped.
  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection at www.lappkabel.de/cpr.
  • Aluminium conductors are lighter and cheaper than copper conductors. They achieve comparable conductivity, provided that at least one to two larger conductor cross-sections are selected.
  • A common core wrapping made of a filling compound ensures additional strength of the cable.
  • Suitable for direct underground installation thanks to tough insulation and sheath material (PVC). The robust materials protect against harmful environmental influences and chemicals.

Applications

  • Power and control cable for fixed installation in the following applications:
  • For indoor and outdoor use
  • In concrete with a temperature below the maximum cable operating temperature of +70 °C according to the VDE standard HD 603/VDE 0276-603 - Part 3-G (point 4) governing PVC cables for direct burial
  • Burial without additional, suitable underground protection according to VDE standard HD 603/VDE 0276-603 - Part 3-G (point 4) governing PVC cables for direct burial: normal minimum installation depth 0.6 m, but at least 0.8 m under roads
  • Suitable for use in AC and DC charging infrastructures for electromobility.
  • For fixed installation in water, air, soil and concrete. In the ground, the minimum installation depth without additional, suitable protection is 0.6 m, and at least 0.8 m under roads.
  • Suitable for medium mechanical stress.
  • Suitable for outdoor use, subject to the temperature range.
  • Can be used in dry, damp or wet environments.
  • Can be used universally for connecting the power supply in buildings and industrial facilities.
  • Suitable for energy distribution in power and converter stations.

Notes

  • Please find our standard lengths at: www.lappkabel.de/kabel-standardlaengen.
  • If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Trade product, not a LAPP product.

KONTAKTIRAJTE NAS

Pošljite nam E-mail ali pa nas pokličite na +386 2 42 13 550