JE-Y(ST)Y...BD EB

Naziv
Koda izdelka
test voltage conductor/conductor
Testna napetost vodnika/opleta
Max. conductor resistance at 20 °C
Cena
Količina
+
JE-Y(ST)Y...BD EB 2X2X0,8
0034120
1 kV
2 kV
36 ?/km
0,87 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-Y(ST)Y...BD EB 4X2X0,8
0034121
1 kV
2 kV
36 ?/km
1,52 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-Y(ST)Y...BD EB 8X2X0,8
0034122
1 kV
2 kV
36 ?/km
2,79 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Ni zaloge, predviden rok dobave: 23. 10. 2026.
+
JE-Y(ST)Y...BD EB 12X2X0,8
0034123
1 kV
2 kV
36 ?/km
3,90 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-Y(ST)Y...BD EB 20X2X0,8
0034125
1 kV
2 kV
36 ?/km
6,22 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-Y(ST)Y...BD EB 32X2X0,8
0034126
1 kV
2 kV
36 ?/km
9,72 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Min. količina za naročanje: 4000
Rok dobave sporočimo po obdelavi naročila.

Benefits

  • Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects)
  • Aluminium-laminated plastic foil static screen with tin-plated drain wire minimises the interference of high frequency, electromagnetic fields
  • Perfect for cost-effective installation, e.g. connections with insulation displacement technology (IDC).
  • Ideal protection against electromagnetic interference thanks to static shielding with aluminium-laminated foil and copper drain wire for the shield contact.
  • With blue outer jacket for use in potentially explosive atmospheres.
  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.

Applications

  • For fixed installation on and under plaster, in dry and damp rooms
  • Industrial electronics
  • Connection cable for fixed installation in industrial control systems, as required in measurement, control, signalling and data applications
  • The PVC outer sheath is somewhat oil-resistant.
  • For use in control, regulation and measurement circuits.
  • For fixed and protected installation in an electrical installation pipe on or under plaster.
  • For use as an installation cable for telecommunications and information processing systems in accordance with DIN VDE 0815.
  • Can be used in dry and damp rooms.
  • For intrinsically safe circuits according to IEC 60079-14 / EN 60079-14 / VDE 0165 (part 1).
  • For use in devices, machines and systems of the "intrinsic safety" ignition protection type ("i").

Notes

  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.
  • Please find our standard lengths at: www.lappkabel.de/kabel-standardlaengen.
  • Trade product, not a LAPP product.

KONTAKTIRAJTE NAS

Pošljite nam E-mail ali pa nas pokličite na +386 2 42 13 550