JE-LiYCY...BD EB

Naziv
Koda izdelka
test voltage conductor/conductor
Testna napetost vodnika/opleta
Max. conductor resistance at 20 °C
Cena
Količina
+
JE-LiYCY...BD EB 2X2X0,5
0034220
1 kV
2 kV
39 ?/km
1,58 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-LiYCY...BD EB 4X2X0,5
0034221
1 kV
2 kV
39 ?/km
2,51 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-LiYCY...BD EB 8X2X0,5
0034222
1 kV
2 kV
39 ?/km
4,18 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-LiYCY...BD EB 12X2X0,5
0034223
1 kV
2 kV
39 ?/km
5,61 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-LiYCY...BD EB 16X2X0,5
0034224
1 kV
2 kV
39 ?/km
7,21 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-LiYCY...BD EB 20X2X0,5
0034225
1 kV
2 kV
39 ?/km
8,55 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-LiYCY...BD EB 24X2X0,5
0034226
1 kV
2 kV
39 ?/km
9,93 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-LiYCY...BD EB 32X2X0,5
0034227
1 kV
2 kV
39 ?/km
13,09 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
JE-LiYCY...BD EB 40X2X0,5
0034228
1 kV
2 kV
39 ?/km
15,74 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Min. količina za naročanje: 4000
Rok dobave sporočimo po obdelavi naročila.

Benefits

  • Overall braid minimises electrical interference
  • Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects)
  • With blue outer jacket for use in potentially explosive atmospheres.
  • The conductor circuits are well decoupled thanks to the twin cabling (TP, Twisted Pair) with short lay lengths.
  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.
  • Ideal protection against electromagnetic interference thanks to copper stranded shielding with a high degree of coverage.

Applications

  • Connection cable for use in electronics and in measurement, control and signal applications
  • This cable is also used as a pulse and data transmission cable
  • JE-LiYCY...BD has also proved to be an efficient connection cable for telephone systems, e.g. paging and intercom systems.
  • For fixed installation on and under plaster, in dry and damp rooms
  • For fixed and protected installation in an electrical installation pipe on or under plaster.
  • For use as an installation cable for telecommunications and information processing systems in accordance with DIN VDE 0815.
  • Especially for environments where electromagnetic compatibility (EMC) is required.
  • For use in control, regulation and measurement circuits.
  • For use in devices, machines and systems of the "intrinsic safety" ignition protection type ("i").
  • The PVC outer sheath is somewhat oil-resistant.
  • For intrinsically safe circuits according to IEC 60079-14 / EN 60079-14 / VDE 0165 (part 1).
  • Can be used in dry and damp rooms.

Notes

  • Please find our standard lengths at: www.lappkabel.de/kabel-standardlaengen.
  • If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Trade product, not a LAPP product.

KONTAKTIRAJTE NAS