J-Y(ST)Y...LG Fire Alarm Cable

Naziv
Koda izdelka
test voltage conductor/conductor
Testna napetost vodnika/opleta
Max. conductor resistance at 20 °C
Cena
Količina
+
(J)-Y(ST)Y...LG 1X2X0,8 BMK
1708001
0.8 kV
0.8 kV
36 ?/km
0,43 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
(J)-Y(ST)Y...LG 4X2X0,8 BMK
1708004
0.8 kV
0.8 kV
36 ?/km
1,29 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
(J)-Y(ST)Y...LG 10X2X0,8 BMK
1708010
0.8 kV
0.8 kV
36 ?/km
3,07 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.
+
(J)-Y(ST)Y...LG 2X2X0,8 BMK
1708002
0.8 kV
0.8 kV
36 ?/km
0,68 €
*
*

Naročilu bo dodan strošek manipulacije in reza 15€ na rez

Na zalogi, predviden rok dobave 5-8 delovnih dni.

Benefits

  • The conductor circuits are well decoupled thanks to the twin cabling (TP, Twisted Pair) with short lay lengths.
  • Ideal protection against electromagnetic interference thanks to static shielding with aluminium-laminated foil and copper drain wire for the shield contact.
  • With red outer jacket for clear identification in the building.
  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.
  • The cable is marked with the phrase “Fire alarm cable” at regular intervals on the sheath. It is therefore used especially for installation in fire alarm systems.
  • Aluminium-laminated plastic foil static screen with tin-plated drain wire minimises the interference of high frequency, electromagnetic fields
  • Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects)

Applications

  • Especially for use in fire alarm systems to connect smoke detectors and fire alarm control panels, for example.
  • For installation on, in or under plaster, in brickwork and in stationary concrete.
  • Can be used in dry and damp rooms.
  • signal transmission
  • For fixed installation on and under plaster, in dry and damp rooms
  • For outdoor use this cable should be installed under plaster only
  • For use as an installation cable for telecommunications and information processing systems in accordance with DIN VDE 0815.
  • The PVC outer sheath is somewhat oil-resistant.

Notes

  • Please find our standard lengths at: www.lappkabel.de/kabel-standardlaengen.
  • If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Trade product, not a LAPP product.

KONTAKTIRAJTE NAS

Pošljite nam E-mail ali pa nas pokličite na +386 2 42 13 550